Fire and Appliance Safety, Part 2

In keeping with the previous post on fire and appliance safety, photographs of some items that have been encountered in previous fire investigations are posted here: the first photo shows an electric stove where the fire originated in the control panel.

                                                                                                    electric-stove-fire

The next photo shows a packaged a/c unit damaged by fire as a result of contact made between a live wire and the edge of an opening in the metal casing.

through-the-wall-unit

The third photo shows a riding lawn mower that ignited, most likely, by the owner’s failure to keep the machine clean between cuttings.

riding-lawn-mower

The next photo is of a paper shredder, also burned, because the machine was not kept clean.  Dust created by shredded paper is just as flammable as any petroleum based fuel if the right conditions exist for ignition.

paper-shredder

The propane gas regulator shown below was installed backwards so that gas was flowing into the outlet port and existing through the vent port.  Since there was no pressure regulation, the cap covering the adjustment, (located in the center) was blown off and the escaping gas ignited.  The homeowner happened to be standing nearby and was severely burned.

improperly-installed-propane-gas-regulator

The next photograph shows a line cord attached to an aquarium pump. The problem was identified as a faulty line cord that was not properly sized for the continuous operation. As a result, the line cord insulation melted and ignited.

aquarium-pump-motor0004

The following photograph shows a coffee maker that ignited and caused a small kitchen fire.  This appliance was destroyed badly enough so that the actual problem was unidentifiable.

coffee-maker-fire

The pipe flange in the next photograph cracked after having been in use for several years.  The leaking gas percolated up through a homeowner’s lawn and ignited; destroying the home as well as damaging a neighbor’s house.

cracked-gas-line-flange

Corrosion of the copper gas line resulted in the leaking of propane gas and a sudden explosion.  The explosion destroyed a residential structure.

fractured-gas-line

“Leave the Friggin Thing Alone!”

It still amazes me that whenever a fire occurs in a machine, like a car or a tractor, somebody who is NOT authorized, has to mess with it. There are still people out there that don’t realize that when they disassemble something they are tampering with evidence.  Even if the case has nothing to do with anything criminal, there is the possibility that a product defect or faulty workmanship might have been responsible for the fire.  But, if the machine (evidence) is disassembled, then evidence is compromised if not destroyed outright.  Disassembly and subsequent testing or examination cannot occur without all interested parties being placed on notice.  Once notified, all parties must be given the chance to participate in formulating a protocol for the disassembly, testing and examination.  After the protocol is formulated, the parties must agree on when and who will perform all necessary functions.  In short, all parties must have access to the same information at the same time.  If not, the potential for spoliation of evidence claims can become an avenue for additional lawsuits or defense, depending on your point of view.  Note that many property insurance policies have a subrogation clause which requires that the policyholder do everything it can to protect their carrier’s right which includes protecting evidence.